How to choose LPD
Count users and simultaneous peak, then calculate litres at storage temperature. Add distribution/standby margin and select the next standard capacity. Large plants require hourly profiles, recirculation and backup analysis.


100-5,000 LPD selection guide
Compare every listed ETC and FPC capacity. SSmart uses 1 evacuated tube per 10 LPD and 1 FPC collector per 125 LPD, while keeping the 150 LPD FPC model at one collector. Final supply follows approved product data and site conditions.
| LPD | Evacuated tubes | Persons* | Area approx. | Tank options | Backup | Warranty |
|---|---|---|---|---|---|---|
| 100 | 10 tubes | 2-4 | 1.2 m² | SS304 / GI / glass-lined MS | Optional electric | As approved make/model |
| 150 | 15 tubes | 4-6 | 1.8 m² | SS304 / GI / glass-lined MS | Optional electric | As approved make/model |
| 200 | 20 tubes | 5-8 | 2.4 m² | SS304 / GI / glass-lined MS | Optional electric | As approved make/model |
| 250 | 25 tubes | 7-10 | 3.0 m² | SS304 / GI / glass-lined MS | Optional electric | As approved make/model |
| 300 | 30 tubes | 8-12 | 3.6 m² | SS304 / GI / glass-lined MS | Optional electric | As approved make/model |
| 500 | 50 tubes | 14-20 | 6.0 m² | SS304 / GI / glass-lined MS | Optional electric | As approved make/model |
| 650 | 65 tubes | 18-26 | 7.8 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 750 | 75 tubes | 21-30 | 9.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 1000 | 100 tubes | 28-40 | 12.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 1200 | 120 tubes | 34-48 | 14.4 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 1500 | 150 tubes | 42-60 | 18.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 1750 | 175 tubes | 50-70 | 21.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 2000 | 200 tubes | 57-80 | 24.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 2500 | 250 tubes | 71-100 | 30.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 2800 | 280 tubes | 80-112 | 33.6 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 3000 | 300 tubes | 85-120 | 36.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 3200 | 320 tubes | 91-128 | 38.4 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 3500 | 350 tubes | 100-140 | 42.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 4000 | 400 tubes | 114-160 | 48.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 4500 | 450 tubes | 128-180 | 54.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
| 5000 | 500 tubes | 142-200 | 60.0 m² | SS304 / GI / glass-lined MS | Project specific | As approved make/model |
* Persons assume roughly 25-35 litres of stored hot water per person per day. Shower, kitchen, laundry, hospital and process loads must be calculated separately.
Count users and simultaneous peak, then calculate litres at storage temperature. Add distribution/standby margin and select the next standard capacity. Large plants require hourly profiles, recirculation and backup analysis.
Compact vacuum-tube solution with strong winter behaviour; inspect tube quality and manage hard-water scaling.
Robust glazed metal collector with serviceable hydraulic circuit; excellent for engineered commercial fields and indirect loops.
Results are educational preliminary estimates, not a quotation, guarantee or electrical/thermal design. Costs and performance vary with location, weather, shade, water quality, equipment, GST, transport, installation, subsidy eligibility, tariff and maintenance. Obtain a site survey and signed proposal.